<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <title>DSpace Community: Research Output of Department of Chemical Engineering</title>
  <link rel="alternate" href="https://shodhratna.thapar.edu:8443/jspui/handle/123456789/62" />
  <subtitle>Research Output of Department of Chemical Engineering</subtitle>
  <id>https://shodhratna.thapar.edu:8443/jspui/handle/123456789/62</id>
  <updated>2026-09-17T10:57:35Z</updated>
  <dc:date>2026-09-17T10:57:35Z</dc:date>
  <entry>
    <title>Simultaneous removal of copper, nickel and zinc metal ions using bulk liquid membrane system</title>
    <link rel="alternate" href="https://shodhratna.thapar.edu:8443/jspui/handle/tiet/962" />
    <author>
      <name>Singh, Ranpreet</name>
    </author>
    <author>
      <name>Mehta, Rajeev</name>
    </author>
    <author>
      <name>Kumar, Vineet</name>
    </author>
    <id>https://shodhratna.thapar.edu:8443/jspui/handle/tiet/962</id>
    <updated>2026-07-20T04:32:08Z</updated>
    <published>2011-01-01T00:00:00Z</published>
    <summary type="text">Title: Simultaneous removal of copper, nickel and zinc metal ions using bulk liquid membrane system
Authors: Singh, Ranpreet; Mehta, Rajeev; Kumar, Vineet
Abstract: One of the novel techniques of mixture component separation is an application of liquid membranes. This paper reveals the ability of liquid membrane in simultaneous transport of mixture components in which a liquid membrane (LM) constitutes a separate phase which separates mixture from an internal receiving phase. In the present work, the experiments were performed for determining the distribution coefficient and Cu, Ni and Zn metal ion removal measurements. Metal distribution coefficients were obtained by simply equilibrating an aqueous solution of the metal ions with an organic liquid membrane containing a complexing agent (D2EHPA), in a separating funnel at 25. °C. Initially, to assure mass balance, samples of both the phases were analyzed by an atomic absorption spectrophotometer. Routinely, only the aqueous phase was analyzed. Distribution coefficients were measured over a broad range of metal ion concentration. The separation of metal ions was analyzed for bulk liquid membrane-cylinder in cylinder setup, by varying the source metal ion concentration. Maximum extraction of 98.8% of zinc, 95.8% of copper and 95.0% of nickel metal ion was achieved at the optimum conditions and maximum removal of the metal ions was in the order Zn &gt; Cu &gt; Ni. © 2011 Elsevier B.V.</summary>
    <dc:date>2011-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Effects of initial discontinuities on nonlinear systems represented by differential equations with terms containing differentials of the input function</title>
    <link rel="alternate" href="https://shodhratna.thapar.edu:8443/jspui/handle/tiet/958" />
    <author>
      <name>Ahuja, Sanjeev Kumar</name>
    </author>
    <id>https://shodhratna.thapar.edu:8443/jspui/handle/tiet/958</id>
    <updated>2026-07-17T10:24:34Z</updated>
    <published>2011-01-01T00:00:00Z</published>
    <summary type="text">Title: Effects of initial discontinuities on nonlinear systems represented by differential equations with terms containing differentials of the input function
Authors: Ahuja, Sanjeev Kumar
Abstract: This article treats the effects of initial jump discontinuities of the inputs on solutions of systems represented by nonlinear second-order ordinary differential equations with terms containing differentials of the input function. A methodology for analysis of discontinuities is presented. In some cases, an initial discontinuity of the calculated impulse response cannot be accounted for in the input function. The value of that discontinuity is thus required for the correct solution of such cases. However, that value cannot be obtained unless the solution profile is known. This paradoxical effect is investigated for different systems and validated by the comparison of experimental and simulated data of nonlinear models of flow-level tanks. A few systems are not affected by discontinuities upon linearization. All others, however, retain their maiden character of being affected or not affected by discontinuities upon linearization. Some interesting cases of calculations of time required for emptying flow-level tanks using impulse responses are also discussed. © Taylor &amp; Francis Group, LLC.</summary>
    <dc:date>2011-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Synthesis of polylactide: Effect of dispersion of the initiator</title>
    <link rel="alternate" href="https://shodhratna.thapar.edu:8443/jspui/handle/tiet/856" />
    <author>
      <name>Kaur, P.</name>
    </author>
    <author>
      <name>Mehta, R.</name>
    </author>
    <author>
      <name>Berek, D.</name>
    </author>
    <author>
      <name>Upadhyay, S.N.</name>
    </author>
    <id>https://shodhratna.thapar.edu:8443/jspui/handle/tiet/856</id>
    <updated>2026-06-25T11:42:37Z</updated>
    <published>2011-01-01T00:00:00Z</published>
    <summary type="text">Title: Synthesis of polylactide: Effect of dispersion of the initiator
Authors: Kaur, P.; Mehta, R.; Berek, D.; Upadhyay, S.N.
Abstract: The ring opening polymerization of L-lactide was studied in bulk using stannous octoate as initiator. In some experiments, triph&#xD;
enylphosphine, a Lewis base was also used as co-initiator. The polymerization was carried out at 130◦C up to 29 h. The monomer was&#xD;
used after recrystallizing three times with dry toluene. Experiments were carried out using a wide range of monomer to initiator ratio.&#xD;
The averages and distributions of molar masses of resulting PLA have been determined by means of size exclusion chromatography,&#xD;
SEC. It is shown that the (mode, process) procedure of dispersion of the catalyst in polymerization system affects the molar mass&#xD;
distribution of the product as is evidenced by the bimodality or even trimodality observed in the SEC chromatograms.</summary>
    <dc:date>2011-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Oxidative degradation of phenol in waste water with the synergetic effect of UV light &amp; H2O2</title>
    <link rel="alternate" href="https://shodhratna.thapar.edu:8443/jspui/handle/tiet/843" />
    <author>
      <name>Garg, A.</name>
    </author>
    <author>
      <name>Bajpai, P.K.</name>
    </author>
    <author>
      <name>Sangal, V.K.</name>
    </author>
    <author>
      <name>Agrawal, P.</name>
    </author>
    <id>https://shodhratna.thapar.edu:8443/jspui/handle/tiet/843</id>
    <updated>2026-06-25T05:57:34Z</updated>
    <published>2011-01-01T00:00:00Z</published>
    <summary type="text">Title: Oxidative degradation of phenol in waste water with the synergetic effect of UV light &amp; H2O2
Authors: Garg, A.; Bajpai, P.K.; Sangal, V.K.; Agrawal, P.
Abstract: H2O2 and O3 when used in water under UV light is &#xD;
particularly well suited for the breakdown of organic molecules &#xD;
as the cleavage of the O-O bond gives OH radicals or "O" atoms. &#xD;
The OH radical is known to be extremely reactive with most &#xD;
organic molecules with H-atom donor properties and promptly &#xD;
attacks such species to produce new types of radicals which may &#xD;
subsequently initiate several radical chain reactions. Also OH &#xD;
radicals are more effective than OR and OOR radicals (R = aryl &#xD;
group) in producing carbon radicals from organics and hence the &#xD;
use of H2O2 as the source of free radicals is very attractive. This &#xD;
photo-oxidation is also called advanced oxidation or enhanced &#xD;
oxidation. &#xD;
Inspite of an extensive research carried out in this area, no &#xD;
reliable kinetic model is available. The UV dose has been changed &#xD;
in a number of studies but very few studies have actually &#xD;
measure the intensity, which of vital importance. &#xD;
Studies on the oxidative degradation of phenol present in dilute &#xD;
aqueous solution in the concentration range between 100 ppm &#xD;
and 1000 ppm with and without hydrogen peroxide were &#xD;
conducted in a batch reactor. The temperature was maintained at &#xD;
about 333 K by circulating cooling water through reactor jacket. &#xD;
Initial conversion of phenolic compounds was extremely high &#xD;
compared with the latter part of the reaction. In presence of &#xD;
hydrogen peroxide, conversion of phenol was found to increase &#xD;
with an increase in hydrogen peroxide / substrate ratio and &#xD;
decrease with increase in initial substrate concentration</summary>
    <dc:date>2011-01-01T00:00:00Z</dc:date>
  </entry>
</feed>

